Oldcastle Precast Modular

 

   
Precast Concrete Cells Exceed Testing Requirements
 
 

 

ASTM F 2322-03 Physical Assault Test:

The Impact Load Test is conducted in accordance with ASTM F- 2322-03 Standard Test Methods for Physical Assault on Fixed Vertical Barriers for Detention and Correctional Facilities and provides a measure of a wall system’s ability to withstand the treatment it can receive under inmate assault conditions. The precast concrete wall is subjected to a series of impact loads from a pendulum ram. The repetitive impact load and quantity are based on the standards established by ASTM and are based on the assumed total number of impacts and impact energy per blow to which the wall would be subjected by a person with a sledgehammer or several persons with a battering ram. Upon completion of the impact testing it is required that no breach be created large enough to allow means of escape.

 
Precast Concrete Prison cells
 
 
ASTM F-2322-03
Cell Impact Test        
  Over 600 Blows to a 4 inch thick precast concrete wall, using an 80 LB Steel Impact Ram, exerting up to 200 foot pounds of force.  
     
Impact Result
TEST RESULTS= Independent Lab Certified Highest Rating - Grade Level No. 1
     
   
Oldcastle Precast Modular - 200 Keystone Drive - Telford, Pennsylvania 18969
   
   